Touch panels for food and beverage production
Industrial operator terminals for ERP, HMI, SCADA and traceability in wet, dusty and hygiene-controlled areas — from dairy and poultry lines to bottled water and date packing.
- IP65 front panel
- IP69 washdown
- 316 stainless steel
- ERP / HMI / SCADA
The production terminal is part of operational risk
Food and beverage plants no longer run on machines and operators alone. ERP, SCADA, MES, warehouse systems, recipe management, batch traceability and lab data are part of every shift on the line — and in the region, halal and food-safety authorities expect that traceability to be reliable.
If an operator terminal stops, cannot be serviced or does not survive the washdown, the problem is no longer just hardware. IWILL offers standard IP65 front-panel configurations for dusty and splash zones, and custom IP69 washdown builds for wet zones, direct cleaning and aggressive chemicals.
One platform for every point on the line
ERP terminal on the line
Enter operations, batches, recipes, quantities and status directly from production.
HMI / SCADA station
Visualise and control processes, machines, temperatures, alarms and production parameters.
Warehouse and QA terminal
Traceability, labelling, goods in and out, lab data and quality checks.
Controlled vendor access point
When a machine or software vendor needs access to one production zone, without opening the whole network.
Standard IP65 panel PCs
For dusty and controlled production areas where the unit is not washed directly and the rear and connectors are protected.

ITPC-A113
Die cast aluminum alloy moulding, fanless Industrial Panel PC; Onboard Intel Celeron J6412,4205U,i3,i5,i7 optional; Support 9V ~ 36V wide voltage...

ITPC-A156
ITPC-A156 is a 15.6 inch Capacitive fanless panel pc,the industrial panel pc ,adopts Intel Celeron J1900 processor with...

ITPC-A600
A600 is a 17 inch Touch Panel PC newly launched by IWILL, Intel celeron J6412,Core i3,i5,i7 processor,Industrial grade multi-touch resistance...

ITPC-A215C
All Aluminum, Fanless Design; Intel Celeron J1900, 4th Generation Core, 6th Generation Core Optional; Adopt HD industrial LCD screen, capacitive five...
IP65 or IP69? The environment decides, not the price
Choose the rating from the real conditions the terminal will face.
| Environment | Recommendation |
|---|---|
| Dry production area with dust | An IP65 front panel may be enough |
| Splashes, humidity or frequent wiping | IP65 front panel, if the rear and connectors are protected |
| Wet zone with direct washing | IP69 washdown build |
| Aggressive chemicals or hygienic zone | IP69 + 316 stainless-steel enclosure |
| Condensation, hose, high pressure | IP69 build with sealed waterproof connectors |
- Dry production area with dust
- RecommendationAn IP65 front panel may be enough
- Splashes, humidity or frequent wiping
- RecommendationIP65 front panel, if the rear and connectors are protected
- Wet zone with direct washing
- RecommendationIP69 washdown build
- Aggressive chemicals or hygienic zone
- RecommendationIP69 + 316 stainless-steel enclosure
- Condensation, hose, high pressure
- RecommendationIP69 build with sealed waterproof connectors
Standard IWILL ITPC configurations are IP65 at the front. IP69 washdown builds are made to order.
Three configurations
ITPC series — standard IP65
For dusty and controlled zones with no direct washing. 10.1" to 21.5", Windows or Linux, COM/USB/LAN connectivity.
High-performance Intel Core panels
For ERP, HMI and SCADA terminals that need more processing power, with the same IP65 front.
Custom IP69 washdown
316 stainless-steel enclosure, IP69 front and rear, sealed waterproof connectors — for direct washing and aggressive cleaning agents.
Network design around the terminal
Segmentation between office, ERP, production, cameras and guest networks, with controlled vendor access and logging.
What to tell us before a quote
Software
ERP, SCADA, Ignition, MES or warehouse system, and its CPU/RAM requirements.
Zone
Dry, dusty, humid or washdown — and whether there is condensation or chemicals.
Screen and mounting
Screen size; VESA, panel mount, stand or machine mount.
OS and ports
Windows 10/11, Windows IoT, Linux or no OS; LAN, COM, USB, HDMI, Wi-Fi/4G.
Quantity
Test units now and the expected rollout across lines.
From dry zones to washdown
- IP65
- standard front panel
- IP69
- custom washdown build
- 316
- stainless-steel option
- 21.5"
- largest screen
Frequently asked questions
Is IP65 enough for food production?
Sometimes. In a dry or controlled zone with only dust or splashes, and with the rear protected, an IP65 front panel can be right. With direct washing, condensation or chemicals, look at an IP69 washdown build.
Can the panel run ERP or Ignition?
Yes, with the right Windows or Linux configuration and confirmed hardware requirements. Before quoting we need the software version, CPU/RAM/SSD needs and required ports.
Do cybersecurity rules require IP65 or IP69 computers?
Not directly. Cybersecurity frameworks focus on risk, continuity and system security. But the operator terminal is part of those systems, so it has to suit both the network design and the physical environment.
Can we start with test units?
Yes. For rollouts across many lines, one or two test units come first; then we fix the final configuration for the remaining points.
Related solutions
Panel PC & HMI
All-in-one touch panel PCs with IP65 fronts for HMI, SCADA clients, kiosks and warehouse terminals.
Read moreIndustrial Automation
Fanless SCADA and HMI computers for plants, process lines and remote sites in heat, dust and vibration.
Read moreGulf Cybersecurity Frameworks
Fanless firewall and VPN appliances as a practical tool for the network controls in Gulf cybersecurity frameworks.
Read moreDo not choose an IP rating from a catalogue